Validate errors [pls post here] [CLOSED]

Gundolf Jahn
Gundolf Jahn
Joined: 1 Mar 05
Posts: 1079
Credit: 341280
RAC: 0

RE: This does not sound

Message 83258 in response to message 83257

Quote:
This does not sound like the same problem described in the recent post.


That's because this thread is about validation errors and you get "Error while computing". ;-)

Your ABP CUDA tasks all error out with

[20:44:54][6804][ERROR] Error acquiring "real" CUDA device!
------> The acquired device is a "Device Emulation (CPU)"
[20:44:54][6804][ERROR] Demodulation failed (error: 1014)!


Perhaps you should disable "Use NVIDIA GPU" in your Einstein@Home preferences until you have found the reason for that problem.

Did you reboot your computer recently? Sometimes that clears something "stuck" with the CUDA device.

Gruß,
Gundolf

Computer sind nicht alles im Leben. (Kleiner Scherz)

Claggy
Claggy
Joined: 29 Dec 06
Posts: 560
Credit: 2699403
RAC: 0

Just one validate error to

Just one validate error to report:

http://einsteinathome.org/workunit/84466697

Claggy

Richard Haselgrove
Richard Haselgrove
Joined: 10 Dec 05
Posts: 2143
Credit: 2959262822
RAC: 707382
dramas
dramas
Joined: 20 Oct 10
Posts: 27
Credit: 31719
RAC: 0

Not an error exactly but this

Not an error exactly but this one has been ready for 10days now and due to expire in 3 days i think.

http://einsteinathome.org/task/201185024

Its rather old and all the others have been fine but that one.

tnx

oops .. better link
http://einsteinathome.org/workunit/85212429

Rob Windgassen
Rob Windgassen
Joined: 16 Aug 10
Posts: 5
Credit: 118675094
RAC: 0

RE: Not an error exactly

Message 83262 in response to message 83261

Quote:

Not an error exactly but this one has been ready for 10days now and due to expire in 3 days i think.

...

http://einsteinathome.org/workunit/85212429


[Marked url as such]

When your wingman times out, a new one will be assigned automatically. You just have to have some patience.

Rob

dramas
dramas
Joined: 20 Oct 10
Posts: 27
Credit: 31719
RAC: 0

RE: RE: Not an error

Message 83263 in response to message 83262

Quote:
Quote:

Not an error exactly but this one has been ready for 10days now and due to expire in 3 days i think.

...

http://einsteinathome.org/workunit/85212429


[Marked url as such]

When your wingman times out, a new one will be assigned automatically. You just have to have some patience.

Rob

Ok thank you, its an old rev and quite large. I read other posts that some in that series have been a problem was all.

(Wingman, Heh i like that :) )

tnx

mikey
mikey
Joined: 22 Jan 05
Posts: 12693
Credit: 1839099286
RAC: 3721

http://einstein.phys.uwm.edu/

http://einsteinathome.org/workunit/84037019

Can someone please tell me why this unit has not been sent back out to more pc's? My pc is the one pc that finished the unit, 2 other people did not and yet it has not been sent back out to anyone else yet!

Claggy
Claggy
Joined: 29 Dec 06
Posts: 560
Credit: 2699403
RAC: 0

Another Validate

Another Validate error:

http://einsteinathome.org/workunit/86007343

Claggy

dramas
dramas
Joined: 20 Oct 10
Posts: 27
Credit: 31719
RAC: 0

Tnx Rob, it took 2 wingmen to

Message 83266 in response to message 83263

Tnx Rob, it took 2 wingmen to process it but it did clear. It was passed on after 2 other wingmen gave up on it i think. lol.. anyway all is well and thank you.

(It did take alot of proc. time so mabey they dident want to wait that long?)

So far all units have passed here FYI

Bernd Machenschalk
Bernd Machenschalk
Moderator
Administrator
Joined: 15 Oct 04
Posts: 4312
Credit: 250585392
RAC: 34471

RE: http://einstein.phys.uw

Message 83267 in response to message 83264

Quote:

http://einsteinathome.org/workunit/84037019

Can someone please tell me why this unit has not been sent back out to more pc's? My pc is the one pc that finished the unit, 2 other people did not and yet it has not been sent back out to anyone else yet!

There were a couple of workunits (ABP, around Oct 1) we need to mess around with manually, which could have had bad side effects on the "transition time" (next time the transitioner will look at them and may e.g. generate more tasks to be sent). In case of this workunit it was set to Nov 28th, at which time the problem should have cleared itself.

I now manually reset the transition time for this workunit, an a new task to be sent out was generated. Unfortunately I can't think of a way to automatically detect all such workunits that are stuck for a while and reset the transition time, normally we would simply have to wait.

BM

BM

Comment viewing options